Pagina 1

paradox.comModules Programming GuideKeypad ModulesAnnunciator ModuleMotion Detector ModulesZone Expansion ModulesAccess Control ModuleVoice Assisted M

Pagina 2 - Table of Contents

10 - Modules Programming GuideRefer to Appendix 1: Programming PGMs on page 52 for the PGM Table. Only Event Groups 000 to 055 can be used to program

Pagina 3 - DNE-K07 V1.4

Modules Programming Guide - 11The keypad will display up to a total of 48 zones, however any zone from 1 to 96 can be selected. Do not assign more

Pagina 4 - Memory Key Connector

12 - Modules Programming GuideDGP2-ANC1B V1.1Annunciator ModuleThe DGP2-ANC1’s serial number is located on the module’s PC board.U = Default Settings

Pagina 5 - [004]

Modules Programming Guide - 13DGP2-50/60 & DGP2-70Motion Detector ModulesRefer to DGP2-50/60/70’s connection drawing on page 42 for the locatio

Pagina 6 - [ 0 0 6 ]

14 - Modules Programming GuideDG85 V1.3Outdoor High-Security Digital Motion Detector ModulesOperational ModesThe DG85 can function in two different o

Pagina 7 - Message Programming

Modules Programming Guide - 15DG467 V1.0360° Ceiling Mounted Motion Detector ModuleOperational ModesThe DG467 can function in two different operati

Pagina 8

16 - Modules Programming GuideDG457 V1.0Digital Glassbreak DetectorOperational ModesThe DG457 can function in two different operational modes: combus

Pagina 9 - DGP2-648BL

Modules Programming Guide - 17DGP2-ZX1 V2.01-zone Expansion ModuleInput speed = Base Time X Time Value (Default: 600ms) U = Default settingSection

Pagina 10

18 - Modules Programming GuideAPR3-ZX4 V1.04-zone Expansion Module* For the Base Time, using Level Programming, press the and buttons to select a

Pagina 11 - Number to a zone

Modules Programming Guide - 19APR-ZX88-zone Expansion Module* For the Base Time, press the and buttons to select a value from 000 to 002 and th

Pagina 12 - DGP2-ANC1B V1.1

Table of ContentsModules Programming Guide...

Pagina 13 - DGP2-50/60 & DGP2-70

20 - Modules Programming GuideMG-RTX3 V1.1Magellan Wireless Expansion ModuleWhen using on an EVO96 version 1.52 or higher without an EVO641, enable o

Pagina 14 - DG85 V1.3

Modules Programming Guide - 21Table 4: PGM Option Programming Event Group Feature Group Start # End #PGMActivation*PGM1 [910] [911] [912] [913]PG

Pagina 15 - DG467 V1.0

22 - Modules Programming GuideDGP-LSN4 and DGP-SUB V1.1Listen-in ModuleU = Default settingSection [001] Substation 1 Partition AssignmentOptions OFF

Pagina 16 - DG457 V1.0

Modules Programming Guide - 23Section [005] General Option 1Options OFF ON[1]Module Tamper InputU Disabled N Enabled[2]Telephone Line MonitoringU

Pagina 17 - DGP2-ZX1 V2.0

24 - Modules Programming GuideSection [011] Substation 3 Page OptionsOptions OFF ON [1] Substation 3 can page Substation 1 N Disabled U E

Pagina 18 - APR3-ZX4 V1.0

Modules Programming Guide - 25[4]Audio Message on Entry Delay N Disabled U Enabled[5]Welcome Audio MessageU Disabled N Enabled[6]Goodbye Audio Mes

Pagina 19 - 8-zone Expansion Module

26 - Modules Programming GuideSection [021] Substation 2 Partition StatusOption OFF ON [1]Plays status of Partition 1 N Disabled U Enable

Pagina 20 - MG-RTX3 V1.1

Modules Programming Guide - 27Using the Memory KeyDownload Contents of the Memory Key to the Listen-In Module1) Insert the Memory Key onto the List

Pagina 21

28 - Modules Programming GuideDGP-ACM124-Wire Access Control ModuleU = Default settingSection [001] Partition AssignmentOption OFF ON [1]

Pagina 22 - DGP-LSN4 and DGP-SUB V1.1

Modules Programming Guide - 29Only Event Groups 000 to 055, 062 and 063 can be used to program the module’s PGM.U = Default settingSection [004] P

Pagina 23

Modules Programming Guide - 3DNE-K07 V1.4 Grafica Graphic LCD Keypad ModuleGrafica Keypads can be used with DGP-848 and DGP-NE96 V1.3 or higher con

Pagina 24

30 - Modules Programming GuideThe DGP-ACM12 has a build-in supervised 1.5A switching power supply and needs to be connected to a transformer. Section

Pagina 25

Modules Programming Guide - 31APR3-PGM4 V2.04-PGM Expansion ModuleU = Default settingRefer to Appendix 1: Programming PGMs on page 52 for the PGM T

Pagina 26

32 - Modules Programming GuideAPR3-ADM2 V2.0Voice Assisted Arm/Disarm ModuleU = Default settingSection Data Description Default[001] __/__/__ (000 to

Pagina 27 - Combus Voltmeter

Modules Programming Guide - 33APR-PRT3 V1.0Integration ModuleU = Default settingSection [001] Partition AssignmentOption OFF ON

Pagina 28 - DGP-ACM12

34 - Modules Programming GuideSection [005] Automatic Printing of Zone Status (25 to 32)Option OFF ON [1]Print Status of Zone 25U Disabl

Pagina 29 - 12345678

Modules Programming Guide - 35Section [010] Automatic Printing of Zone Status (65 to 72)Option OFF ON [1]Print Status of Zone 65 (EVO1

Pagina 30

36 - Modules Programming GuideRefer to Appendix 1: Programming PGMs on page 52 for the PGM Table. Only Event Groups 000 to 055 can be used to program

Pagina 31 - APR3-PGM4 V2.0

Modules Programming Guide - 37Manual Printing ProgrammingSection Data Description Default[027] __/__/__ (000 to 255)** Miscellaneous Events (Event

Pagina 32 - APR3-ADM2 V2.0

38 - Modules Programming GuideDGP2-PS17 V1.0Power SupplyA 40VA transformer is required when selecting the 850mA battery charge current. Using a 20VA

Pagina 33 - APR-PRT3 V1.0

Modules Programming Guide - 39Module Connection DrawingsModule LED IndicationsGreen LOCATE LED (sometimes seen as LOC or LC):Power Up: Remains illu

Pagina 34

4 - Modules Programming GuideUsing the Memory KeyDownload Contents of the Memory Key to the Grafica Keypad:1) Insert the Memory Key onto the keypad’s

Pagina 35

40 - Modules Programming GuideGrafica Graphic LCD Keypad Module (DNE-K07)Please Note: The Grafica keypad is best viewed at an angle between 20° and -

Pagina 36

Modules Programming Guide - 41EVO641/EVO641R Access Control ConnectionsLCD Keypad Module (EVO641/EVO641R) 48-Zone LED Keypad Module (DGP2-648)Memor

Pagina 37 - Manual Printing Programming

42 - Modules Programming GuideAnnunciator Module (DGP2-ANC1B)Outdoor High-Security Digital Motion Detector Module (DG85)Remove B from any Annunciator

Pagina 38 - DGP2-PS17 V1.0

Modules Programming Guide - 43Motion Detector Modules (DGP2-50/60/70)PCB Height AdjustmentDGP2-50/60/70 is designed for optimal performance at a he

Pagina 39 - Module Connection Drawings

44 - Modules Programming GuideMagellan Wireless Expansion Module (MG-RTX3)Digital Ceiling Mounted Motion Detector Module (DG467)4-PGM Expansion Modul

Pagina 40

Modules Programming Guide - 454-zone Expansion Module (APR3-ZX4)One-zone Expansion Module (DGP2-ZX1)Connect the detection devices to the APR3-ZX4 i

Pagina 41 - Z1 terminal

46 - Modules Programming GuideListen-in Modules (DGP-LSN4 & DGP-SUB1)InTouch Voice-Assisted Arm/Disarm Module (APR3-ADM2)Reset JumperFirmware Upg

Pagina 42 - PCB HEIGHT ADJUSTMENT

Modules Programming Guide - 47Intergration module (APR-PRT3) 1) LED feedback2) 25-Pin Parallel Port: Connect the Printer Module’s 25-pin parallel p

Pagina 43 - PCB Height Adjustment

48 - Modules Programming GuideAccess Control Module (DGP-ACM12)Splice all cables hereConnecting Access Control Devices to the DGP2-ACM12Caution: Disc

Pagina 44 - PCB arrow with

Modules Programming Guide - 49Power Supply Module (DGP2-PS17) Door Contact Module (DGP2-ZC1)Caution: Disconnect battery before replacing the fuse.F

Pagina 45 - Detector

Modules Programming Guide - 5EVO641/EVO641R V1.0832-Character Blue LCD Keypad ModuleThe keypad’s serial number can be found on the keypad’s PC boar

Pagina 46

50 - Modules Programming GuideHub and Bus Isolator Module (APR3-HUB2)From other modules or a Spectra or Digiplex control panelTo other combus modules

Pagina 47 - Indications on page 39

Modules Programming Guide - 51VDMP3 Plug-in Voive DialerFor programming method, refer to panel programming guide.Attach support pin to EVO panel an

Pagina 48 - Paradoor 460

52 - Modules Programming GuideAppendix 1: Programming PGMSA PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM

Pagina 49

Modules Programming Guide - 53004Non-reportable EventTLM Trouble (see NOTE 3 on page 58)000 000Smoke detector reset 001 001Arm with no entry delay

Pagina 50 - From other modules or a

54 - Modules Programming Guide012Special Arming000Auto Arming 000 000Arming by WinLoad 001 001Late to Close 002 002No Movement Arming 003 003Partial

Pagina 51 - VDMP3 Plug-in Voive Dialer

Modules Programming Guide - 55022Special Disarm Events000Auto Arm Cancelled 000 000One-touch Stay/Instant Disarm 001 001Disarming with WinLoad 002

Pagina 52 - Appendix 1: Programming PGMS

56 - Modules Programming Guide037Trouble Restore000TLM Trouble 000 000AC Failure 001 001Battery Failure 002 002Auxiliary Current Limit 003 003Bell Cu

Pagina 53

Modules Programming Guide - 57047Late to Arm by User000 User Codes 001 to 255 001 to 255 001 to 255001 User Codes 256 to 511 000 to 255 000 to 2550

Pagina 54

58 - Modules Programming GuideNOTE 1: 000 = Occurs in all partitions enabled in the system (refer to the appropriate control panel Programming Guide)

Pagina 55

Modules Programming Guide - 59** Keyswitch‡ Refer to the Magellan™ Reference and Installation Manual for remote control button programming instruct

Pagina 56

6 - Modules Programming Guide† Section/option is only available with EVO641R.‡ Section/option is only available with EVO641.Section [005] Beep on Tr

Pagina 57

paradox.comPRINTED IN CANADA 09/2007 MODULES-EP14For technical support in Canada or the U.S., call 1-800-791-1919, Monday

Pagina 58

Modules Programming Guide - 7‡ Section/option is only available with EVO641.Only Event Groups 000 to 055 and 070 can be used to program the module’

Pagina 59 - ** Keyswitch

8 - Modules Programming GuideTable 3: Special CharactersUsing the Memory KeyDownload Contents of the Memory Key to the LCD Keypad1) Insert the Memory

Pagina 60

Modules Programming Guide - 9DGP2-648BL48-zone LED Keypad ModuleThis model does not support installer programming capabilities, therefore you canno

Commenti su questo manuale