18 - Digiplex Modules Programming Guide
8-zone Expansion Module
* For the Base Time, using Level Programming (refer to page 1), press the and buttons to select a value from 000 to 002 and then press [ENTER].
Base Time Multipliers: 000 = 15 ms, 001 = 1 second, 002 = 1 minute.
Refer to Appendix 1: Programming PGMs on page 41 for the PGM Table. Only Event Groups 000 to 055 can be used to program the
module’s PGM.
U = Default setting
SECTION [001] : General Options
Option OFF ON
[1] Tamper Recognition
ON = Input 8 (Z8) becomes tamper input
U Disabled
N Enabled
[2] PGM Deactivation After
U
Deactiva-
tion Event
N
PGM Timer
[3] PGM normal state
U N.O.
N N.C.
[4]
PGM Base Time
U 1 second
N 1 minute
[5] to [8] Future Use N N/A N N/A
Input Speed Base Time (000-002)* Time Value (000-255) Default Input Speed Base Time (000-002)* Time Value (000-255) Default
Input 001 / 009
[002]
___/___/___
[003]
___/___/___ 600ms Input 005 / 013
[010]
___/___/___
[011]
___/___/___ 600ms
Input 002 / 010
[004]
___/___/___
[005]
___/___/___ 600ms Input 006 / 014
[012]
___/___/___
[013]
___/___/___ 600ms
Input 003 / 011
[006]
___/___/___
[007]
___/___/___ 600ms Input 007 / 015
[014]
___/___/___
[015]
___/___/___ 600ms
Input 004 / 012
[008]
___/___/___
[009]
___/___/___ 600ms Input 008 / 016
[016]
___/___/___
[017]
___/___/___ 600ms
Section Data Description Default
[018] __/__/__ (000 to 255; see option [4] in section [001])PGM Timer 005
Event Group Feature Group Start # End #
Section Section Section Section
PGM Activation [019] __/__/__ [020] __/__/__ [021] __/__/__ [022] __/__/__
PGM Deactivation [023] __/__/__ [024] __/__/__ [025] __/__/__ [026] __/__/__
Section Description
[030] Test PGM: Activates the PGM for 8 seconds to verify if the PGM is functioning properly.
APR3-ZX8 V2.0