Digiplex Modules Programming Guide - 29
Power Supply Module
Refer to Appendix 1: Programming PGMs on page 41 for the PGM Table. Only Event Groups 000 to 055 can be used to program the
module’s PGM.
U = Default setting
SECTION [001] : General Options
Option OFF ON
A 40VA transformer is required when selecting the 850mA
battery charge current. Using a 20VA transformer with a
battery charge current of 850mA may damage the system.
[1] Tamper Recognition
U Disabled
N Enabled
[2] Battery Charge Current
U 350mA
N 850mA
[3] PGM Deactivation After
U
Deactiva-
tion Event
N
PGM Timer
[4] PGM Base Time
U 1 second
N 1 minute
[5] to [8] Future Use N N/A N N/A
Section Data Description Default
[002] __/__/__ (000 to 255 x 1 minute; 000 = Instant) AC failure report delay 000
[003] __/__/__ (000 to 255; refer to option [4] in section [001])PGM Timer 005
Event Group Feature Group Start # End #
Section Section Section Section
PGM Activation [004] __/__/__ [005] __/__/__ [006] __/__/__ [007] __/__/__
PGM Deactivation [008] __/__/__ [009] __/__/__ [010] __/__/__ [011] __/__/__
Section Description
[020] Test PGM: Activates the PGM for 8 seconds to verify if the PGM is functioning properly.
DGP2-PS17 V1.0